Phys Med ; 67: 50-57, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31669670

RESUMEN

PURPOSE: Gallium-66 is a non-conventional positron emitter that stands out not only for its high potential to label peptides, proteins and antibodies, but also because it can provide spatio-temporal information of relatively slow physiological processes in the body due to its conveniently long half-life of 9.5 h. However, 66Ga emits the most energetic positrons for PET imaging. The lack of information of the positron range effect on spatial resolution for this positron emitter is an issue, particularly in preclinical imaging. METHODS: The line spread function (LSF) in tissue-equivalent materials with densities between 0.2 and 1.93 g/cm3 was obtained with 66Ga and 18F. A complementary study with the NEMA NU 4-2008 image quality phantom is also included. RESULTS: High-energy positrons moving in lower density materials produce far-reaching activity distributions. The LSFs were characterized with Lorentzian-Gaussian fits, with spatial resolution (FWHM) in the 2.14-3.2 mm range, and long tails extending a few tens of mm depending on the material type and density. A narrowing of the LSF was observed for lung-equivalent materials, indicating the lack of enough material for the positron annihilation to take place. The NEMA NU 4-2008 image quality phantom produced blurred images, notoriously observed in the hot and cold cylinders used for evaluation of recovery coefficients (RC) and spill-over ratios (SOR), producing very low RC and very large SOR. CONCLUSIONS: Quantitative PET imaging with the non-conventional 66Ga is hampered due to the large range of its high-energy positrons affecting both spatial resolution and activity concentration quantification.


Asunto(s)
Electrones , Radioisótopos de Galio , Tomografía de Emisión de Positrones/métodos , Animales , Procesamiento de Imagen Asistido por Computador
2.
Sci Rep ; 8(1): 17310, 2018 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-30470826

RESUMEN

Lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) are the scintillator materials most widely used today in PET detectors due to their convenient physical properties for the detection of 511 keV annihilation photons. Natural lutetium contains 2.6% of 176Lu which decays beta to excited states of 176Hf producing a constant background signal. Although previous works have studied the background activity from LSO/LYSO, the shape of the spectrum, resulting from ß-particle and γ radiation self-detection, has not been fully explained. The present work examines the contribution of the different ß-particle and γ-ray interactions to provide a fuller comprehension of this background spectrum and to explain the differences observed when using crystals of different sizes. To this purpose we have shifted the continuous ß-particle energy spectrum of 176Lu from zero to the corresponding energy value for all combinations of the isomeric transitions of 176Hf (γ-rays/internal conversion). The area of each shifted ß-spectrum was normalized to reflect the probability of occurrence. To account for the probability of the γ-rays escaping from the crystal, Monte Carlo simulations using PENELOPE were performed in which point-like sources of monoenergetic photons were generated, inside LYSO square base prisms (all 1 cm thick) of different sizes: 1.0 cm to 5.74 cm. The analytic distributions were convolved using a varying Gaussian function to account for the measured energy resolution. The calculated spectra were compared to those obtained experimentally using monolithic crystals of the same dimensions coupled to SiPM arrays. Our results are in very good agreement with the experiment, and even explain the differences observed due to crystal size. This work may prove useful to calibrate and assess detector performance, and to measure energy resolution at different energy values.

3.
Phys Med ; 42: 19-27, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29173915

RESUMEN

We present the performance evaluation of a large-area detector module based on the ArrayC-60035-64P, an 8×8 array of tileable, 7.2mm pitch, silicon photomultipliers (SiPM) by SensL, covering a total area of 57.4mm×57.4mm. We characterized the ArrayC-60035-64P, operating at room temperature, using LYSO pixelated crystal arrays of different pitch sizes (1.075, 1.430, 1.683, 2.080 and 2.280mm) to determine the resolvable crystal size. After an optimization process, a 7mm thick coupling light guide was used for all crystal pitches. To identify the interaction position a 16-channel (8 columns, 8 rows) symmetric charge division (SCD) readout board together with a center-of-gravity algorithm was used. Based on this, we assembled the detector modules using a 40×40 LYSO, 1.43mm pitch array, covering the total detector area. Calibration was performed using a 137Cs source resulting in excellent crystal maps with minor geometric distortion, a mean 4.1 peak-to-valley ratio and 9.6% mean energy resolution for 662keV photons in the central region. The resolvability index was calculated in the x and y directions with values under 0.42 in all cases. We show that these large area SiPM arrays, combined with a 16-channel SCD readout board, can offer high spatial resolution, without processing a big number of signals, attaining excellent energy resolution and detector uniformity.


Asunto(s)
Tomografía de Emisión de Positrones/instrumentación , Calibración , Radioisótopos de Cesio , Diseño de Equipo , Radioisótopos de Flúor , Mamografía/instrumentación , Conteo por Cintilación/instrumentación , Silicio
4.
Phys Med Biol ; 61(17): 6307-21, 2016 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-27494279

RESUMEN

In this work an experimental investigation was carried out to study the effect that positron range has over positron emission tomography (PET) scans through measurements of the line spread function (LSF) in tissue-equivalent materials. Line-sources consisted of thin capillary tubes filled with (18)F, (13)N or (68)Ga water-solution inserted along the axis of symmetry of cylindrical phantoms constructed with the tissue-equivalent materials: lung (inhale and exhale), adipose tissue, solid water, trabecular and cortical bone. PET scans were performed with a commercial small-animal PET scanner and image reconstruction was carried out with filtered-backprojection. Line-source distributions were analyzed using radial profiles taken on axial slices from which the spatial resolution was determined through the full-width at half-maximum, tenth-maximum, twentieth-maximum and fiftieth-maximum. A double-Gaussian model of the LSFs was used to fit experimental data which can be incorporated into iterative reconstruction methods. In addition, the maximum activity concentration in the line-sources was determined from reconstructed images and compared to the known values for each case. The experimental data indicates that positron range in different materials has a strong effect on both spatial resolution and activity concentration quantification in PET scans. Consequently, extra care should be taken when computing standard-uptake values in PET scans, in particular when the radiopharmaceutical is taken up by different tissues in the body, and more even so with high-energy positron emitters.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacocinética , Tejido Adiposo/diagnóstico por imagen , Animales , Hueso Esponjoso/diagnóstico por imagen , Hueso Cortical/diagnóstico por imagen , Electrones , Pulmón/diagnóstico por imagen , Distribución Tisular , Agua/química